Cobalt Digital Inc Cobalt NASRaQ Bedienungsanleitung Seite 197

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 334
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 196
Active Monitor
Cobalt RaQ XTR User Manual 175
RAID failure
For a failed hard disk drive, Active Monitor indicates with a graphic (see
Figure 87) the particular drive that has failed.
If a drive in a RAID-0 configuration fails, the RaQ XTR server fails. If a drive in
a RAID-1 or RAID-5 configuration fails and the server is still operating, the
system indicates the non-RAID status in three ways:
An email is sent to the RaQ XTR Administrator.
Under Server Management > Active Monitor, the Disk Integrity (RAID)
circle changes to red.
The “C” logo badge on the front panel of the server blinks.
To view the status of the RAID configuration:
1. Select Server Management > Active Monitor. The status tables appear.
2. Click the green magnifying-glass icon to see the detailed view of Disk
Integrity (RAID).
Figure 87. Failed hard disk drive
Seitenansicht 196
1 2 ... 192 193 194 195 196 197 198 199 200 201 202 ... 333 334

Kommentare zu diesen Handbüchern

Keine Kommentare